Thank you for purchase of "HITACHI INVERTER". This manual
explains about treatment of "SJ-DG (digital input option)". By reading this
manual and an instruction manual of inverter use practically for
installation, maintenance, and inspection. After reading this manual, keep
it handy for future reference
Make sure to reach this manual to the end user.
After reading this manual, keep it handy for future reference
SJ300/L300P SERIES
(DIGITAL INPUT OPTION)

Table of Contents

1
2
4
6
7
NB617X

Advertisement

loading

Summary of Contents for Hitachi SJ-DG

  • Page 1: Table Of Contents

    INSTRUCTION MANUAL Thank you for purchase of “HITACHI INVERTER”. This manual explains about treatment of “SJ-DG (digital input option)”. By reading this manual and an instruction manual of inverter use practically for installation, maintenance, and inspection. After reading this manual, keep it handy for future reference Make sure to reach this manual to the end user.
  • Page 2 Request Thank you for purchase of “HITACHI INVERTER”. This manual explains about handling of “SJ-DG (digital input option)”. This instruction manual explains about treatment and maintenance of “SJ-DG”. Before using the product, carefully read this manual with the instruction manual of inverter, and keeps it handy for quick reference of operator and maintenance inspector.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Carefully read this manual and all of the warning labels attached to the inverter before installing, operating, maintaining, or inspecting it. Safety precautions are classified into “Warning” and “Caution” in this manual. : Indicates a potentially hazardous situation which, if not avoided, can result in serious injury or WARNING death.
  • Page 4 Otherwise, there is a danger of electric shock and/or fire. Maintenance, Inspection and Part Replacement: Wait at least 10 minutes after turning off the input power supply before performing maintenance and inspection. (Confirm the charge lamp on the inverter is off, checks direct current voltage between P-N terminals and confirm it is less than 45V.)
  • Page 5 SAFETY PRECAUTIONS...
  • Page 7: Chapter1 Introduction

    Any explanation and repair after the warranty period (one-year) shall be charged to the purchaser. And also any explanation and repair out of warranty mentioned above, even within warranty period, shall be charged to the purchaser. If you require the toll repair, please contact your Hitachi Distributor. 1.3 OUTLINE OF THE PRODUCT If this option printed board is installed to SJ300/L300P series, it is possible to input setting frequency, acceleration time setting, deceleration time setting, torque limit setting, and position setting in digital.
  • Page 8: Chapter2 Installation Method Of Printed Board

    CHAPTER 2 INSTALLATION METHOD OF PRINTED BOARD 2.1 INSTALLATION METHOD OF PRINTED BOARD As the following Figure 2-1, exactly connect option board 1 or 2 to the holes of the four corners and the connector part of the back. Be sure to fit them to the guide post for positioning of option printed board and screw holes for fixing.
  • Page 9: Chapter3 Wiring Connecting

    3.1 TERMINAL ASSIGNMENT OF DIGITAL INPUT OPTION BOARD Figure 3-1a shows terminal assignment, Figure 3-1b shows terminal standard connection. TM1 Terminal assignment SEQ CMB D15 D14 D13 D12 D11 In case of sink type interface, power is supplied to input terminal (D0 to D15, STRB) by short circuit between P24B terminal and PLCB terminal.
  • Page 10 In case of using external power source YTR48 type Output module Table 3-2b Connection of output terminal(SEQ CMB) to programable controller Sink logic In case of using internal interface power source P24B DC24V PLCB STRB SJ-DG DC24 STRB DC24V SJ-DG Source logic P24B PLCB Short Circuit...
  • Page 11 DC24V SJ-DG 3.3 SPECIFICATION OF TERMINAL Table 3-3 shows specification of terminal. Terminal Terminal name symbol D15 to D0 (Hereinafter Data input terminal called as Input Strobe terminal STRB (Data take in command signal terminal) Sequence error signal (Data input error signal...
  • Page 12: Chapter4 Setting

    (SJ300, L300 series) related to operating SJ-DG. Make sure to refer to “CHAPTER 3 OPERATION”, “CHAPTER 4 EXPLANATION OF FUNCTION” of the instruction manual of the inverter, and set exactly. Table 4-3 Table of setting items of inverter related to SJ-DG Code Function name...
  • Page 13 It is possible to select input mode by combination of dip switch and rotary switch on the option printed board. Table 4-4 shows table of input mode. Rotary Dip switch switch TYPE CODE Switch No. Setting code (One time input mode at OFF) (Binary...
  • Page 14 CHAPTER 4 SETTING 4.5 PRECAUTIONS AT SETTING OF SWITCH (1) In case of setting rotary switch code to (5, 7 to F) in one time input mode, sequence error outputs just after power on of inverter. (2) In case of setting rotary switch code to (B to F) in 2 dividing input mode, sequence error outputs just after power on of inverter.
  • Page 15: Chapter5 Function

    5.1 FUNCTION 5.1.1 ONE TIME BINARY INPUT It is possible to select frequency setting, torque limit setting or position setting of one time data input by rotary switch CODE. Figure 5.1.1shows data bit construction of one time binary input. (Example of setting) In case of setting frequency to 60.0Hz by 0.1Hz resolution (Higher) Figure 5.1.1 Data bit construction of one time binary input...
  • Page 16 CHAPTER 5 FUNCTION Setting data 4 Precaution Refer to 5.3 ”DATA INPUT TIMING” for signal input timing. 5.1.3 TWO DIVIDING BINARY INPUT It is possible to change setting data by twice input of data, higher data and lower data. And it is possible to select frequency setting, torque limit setting, acceleration and deceleration time setting or position setting by change of classification code (Refer to Figure 5.2 Table of classification code.).
  • Page 17 5.1.4 TWO DIVIDING BCD INPUT It is possible to change setting data by twice input of data, higher data and lower data. And it is possible to select frequency setting, torque limit setting, acceleration and deceleration time setting, or position setting by change of classification code (Refer to Figure 5.2 Table of classification code.).
  • Page 18 CHAPTER 5 FUNCTION 5.2 CLASSIFICATION CODE Table 5.2 shows table of classification code. Make sure to input classification code in order, higher code and then lower code. 5.3 DATA INPUT TIMING 5.3.1 TIMING AT ONE TIME INPUT Take in data in on level that strobe signal. Let on/off time of strobe signal be more than 20ms. Be in state of on. And if data indefinite area is more than 5ms, turn strobe signal off in order to satisfy Figure 5.3.1 timing chart of one time data input.
  • Page 19 5.4 NOTICE AT DATA INPUT While inputting the data by terminal of SJ-DG, notice the following items. (1) Each input is possible to set within data range of the inverter in every setting item. If inputting without data range, sequence error is outputted and data input is invalid (previous data is kept).
  • Page 20 CHAPTER 5 FUNCTION 9999 However, Hz set actually is calculated in max frequency Hz and, value which is ignored less than is setting frequency.