Code
Function name
b078 Cumulative input power data clearance
Cumulative input power display gain
b079
setting
b082 Start frequency adjustment
b083 Carrier frequency setting
Initialization mode
b084
(parameters or trip history)
b085 Country for initialization
b086 Frequency scaling conversion factor
b087 STOP key enable
b088 Restart mode after FRS
b089 Automatic carrier frequency reduction
b090 Dynamic braking usage ratio
b091 Stop mode selection
b092 Cooling fan control
b095 Dynamic braking control
b096 Dynamic braking activation level
b098 Thermistor for thermal protection control
b099 Thermal protection level setting
b100 Free-setting V/f frequency (1)
b101 Free-setting V/f voltage (1)
b102 Free-setting V/f frequency (2)
b103 Free-setting V/f voltage (2)
b104 Free-setting V/f frequency (3)
b105 Free-setting V/f voltage (3)
b106 Free-setting V/f frequency (4)
b107 Free-setting V/f voltage (4)
b108 Free-setting V/f frequency (5)
b109 Free-setting V/f voltage (5)
b110 Free-setting V/f frequency (6)
b111 Free-setting V/f voltage (6)
b112 Free-setting V/f frequency (7)
b113 Free-setting V/f voltage (7)
b120 Brake control enable
b121 Brake wait time for release
b122 Brake wait time for acceleration
b123 Brake wait time for stopping
b124 Brake wait time for confirmation
b125 Brake release frequency setting
b126 Brake release current setting
b127 Braking frequency
b130 Overvoltage suppression enable
b131 Overvoltage suppression level
Acceleration and deceleration rate at
b132
overvoltage suppression
b133 Overvoltage suppression proportional gain 0.00 to 2.55
b134 Overvoltage suppression Integral time
b141 Output loss detection enable
b142 Output loss detection sensibility
b164 Automatic return to initial display
b166 Data Read/Write select
b180 Initialization trigger
(Note) < >indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : variable torque mode, you can set CT or VT by b049.
Monitored data or setting
Clearance by setting "01" and pressing the STR key
1. to 1000.
0.10 to 9.99 (Hz)
0.5~15.0(kHz) <0.5~10.0(kHz)> (In case of CT)
0.5~12.0(kHz) (In case of VT)
00 (disabled), 01 (clearing the trip history), 02 (initializing the data),
03 (clearing the trip history and initializing the data),
04 (clearing the trip history and initializing the data and EzSQ program)
00 (JPN), 01(EU), 02(USA)
0.1 to 99.0
00 (enabling), 01 (disabling), 02 (disabling only the function to stop)
00 (starting with 0 Hz), 01 (starting with matching frequency),
02 (starting with active matching frequency)
00: invalid, 01: valid
0.0 to 100.0 (%)
00 (deceleration until stop), 01 (free-run stop)
00 (always operating the fan), 01 (operating the fan only during
inverter operation [including 5 minutes after power-on and power-off])
00 (disabling), 01 (enabling [disabling while the motor is topped]),
02 (enabling [enabling also while the motor is topped])
330 to 390 (V) (200 V class model),
660 to 780 (V) (400 V class model)
00 (disabling the thermistor), 01 (enabling the thermistor with PTC),
02 (enabling the thermistor with NTC)
0. to 9999. ()
0. to "free-setting V/f frequency (2)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (1)" to "free-setting V/f frequency (3)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (2)" to "free-setting V/f frequency (4)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (3)" to "free-setting V/f frequency (5)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (4)" to "free-setting V/f frequency (6)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (5)" to "free-setting V/f frequency (7)" (Hz)
0.0 to 800.0 (V)
"free-setting V/f frequency (6)" (Hz) to 400. (Hz)
0.0 to 800.0 (V)
00 (disabling), 01 (enabling)
0.00 to 5.00 (s)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 x "rated current" to 2.00 x "rated current" (A)
0.00 to 99.99, 100.0 to 400.0 (Hz)
00 (disabling restraint), 01 (controlled deceleration),
02 (enabling acceleration with decelerating), 03 (enabling acceleration)
330 to 390 (V) (200 V class), 660 to 780 (V) (400 V class)
0.10 to 30.00 (s)
0.000 to 9.999 / 10.00 to 65.53 (s)
00 (disabling), 01 (enabling)
1.~100.(%)
00 (disabling), 01 (enabling)
00 (Read/Write OK), 01 (Protected)
00 (Initialization disable), 01 (Perform initialization)
4 - 9
Chapter 4
List of Data Settings
Default
FF FEF FUF b031≠10 b031=10
5.0<3.0>(CT)
3.0(VT)
00
360/720
Rated current
380/760
Change during
RUN operation
00
Allowed Allowed
1.
Allowed Allowed
0.50
Not
Allowed
Not
Not
00
Not
Not
01
02
Not
Not
1.0
Allowed Allowed
00
Not
Allowed
00
Not
Allowed
00
Not
0.0
Not
Allowed
00
Not
Allowed
01
Not
Allowed
01
Not
Allowed
Not
Allowed
00
Not
Allowed
3000.
Not
Allowed
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
0.
Not
Not
0.0
Not
Not
00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
Not
Allowed
0.00
Not
Allowed
00
Not
Allowed
Not
Allowed
1.00
Not
Allowed
0.50
Allowed Allowed
0.060
Allowed Allowed
00
Not
Allowed
10.
Allowed Allowed
00
Allowed Allowed
00
Not
Allowed
00
Not
Not