Hitachi SJ700D-3 SERIES Quick Reference Manual page 63

Hide thumbs Also See for SJ700D-3 SERIES:
Table of Contents

Advertisement

Code
Function name
A041 Torque boost method selection
A241 Torque boost method selection, 2nd motor
A042 Manual torque boost value
A242 Manual torque boost value, 2nd motor
A342 Manual torque boost value, 3rd motor
A043 Manual torque boost frequency adjustment
Manual torque boost frequency adjustment,
A243
2nd motor
A343 Manual torque boost frequency adjustment,
3rd motor
V/F characteristic curve selection,
A044
1st motor
V/F characteristic curve selection,
A244
2nd motor
V/F characteristic curve selection,
A344
3rd motor
A045 V/f gain setting
A046 Voltage compensation gain setting for
automatic torque boost. 1st motor
Voltage compensation gain setting for
A246
automatic torque boost, 2nd motor
Slippage compensation gain setting for
A047
automatic torque boost, 1st motor
Slippage compensation gain setting for
A247
automatic torque boost, 2nd motor
A051 DC braking enable
A052 DC braking frequency setting
A053 DC braking wait time
A054 DC braking force during deceleration
A055 DC braking time for deceleration
DC braking/edge or level detection
A056
for [DB] input
A057 DC braking force for starting
A058 DC braking time for starting
A059 DC braking carrier frequency setting
A061 Frequency upper limit setting
A261 Frequency upper limit setting, 2nd motor
A062 Frequency lower limit setting
A262 Frequency lower limit setting, 2nd motor
A063 Jump (center) frequency setting 1
A064 Jump (hysteresis) frequency width setting 1
A065 Jump (center) frequency setting 2
A066 Jump (hysteresis) frequency width setting 2
A067 Jump (center) frequency setting 3
A068 Jump (hysteresis) frequency width setting 3
A069 Acceleration stop frequency setting
A070 Acceleration stop time frequency setting
A071 PID Function Enable
A072 PID proportional gain
A073 PID integral time constant
A074 PID derivative gain
A075 PV scale conversion
A076 PV source setting
A077 Output of inverted PID deviation
A078 PID variation range
A079 PID feed forward selection
(Note) < > indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : Variable torque mode, you can set CT or VT by b049.
Monitored data or setting
00 (manual torque boost),
01 (automatic torque boost)
0.0 to 20.0 (%)
0.0 to 50.0 (%)
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control),
04 (0Hz sensorless vector control)(only CT),
05(vector with sensor)(only CT)
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control),
04 (0Hz sensorless vector control)(only CT)
00(VC), 01(VP)
20. to 100. (%)
0. to 255.
0. to 255.
00 (disabling), 01 (enabling), 02 (set frequency only)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 5.0 (s)
0. to 100. (%) <0. to 80. (%)> (In case of CT)
0. to 70. (%) <0. to 50. (%)> (In case of VT)
0.0 to 60.0 (s)
00 (edge operation), 01 (level operation)
0. to 100. (%) <0. to 80. (%)> (In case of CT)
0. to 70. (%) <0. to 50. (%)> (In case of VT)
0.0 to 60.0(s)
0.5 to 15.0(kHz) <0.5 to 10.0 (kHz) > (In case of CT)
0.5 to 12.0(kHz) <0.5 to 8.0 (kHz) > (In case of VT)
0.00 or "1st minimum frequency limit" to
"maximum frequency" (Hz)
0.00 or "2nd minimum frequency limit" to
"maximum frequency, 2nd motor" (Hz)
0.00 or "start frequency" to "maximum frequency limit" (Hz)
0.00 or "start frequency" to "maximum frequency,
2nd motor limit" (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 10.00 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 10.00 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 10.00 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 60.0 (s)
00 (disabling), 01 (enabling), 02 (enabling inverted-data output)
0.2 to 5.0
0.0 to 999.9, 1000. to 3600. (s)
0.00 to 99.99, 100.0 (s)
0.01 to 99.99
00 (input via OI), 01 (input via O), 02 (external communication),
03 (pulse-string frequency input), 10 (operation result output)
00(OFF), 01 (ON)
0.0 to 100.0 (%)
00 (disabled), 01 (O input), 02 (OI input), 03 (O2 input)
4 - 5
Chapter 4
List of Data Settings
Default
FF FEF FUF
5.0<3.0> (CT)
3.0 (VT)
Change during
RUN operation
b031≠10
b031=10
00
Not
Not
00
Not
Not
1.0
Allowed Allowed
Allowed Allowed
1.0
1.0
Allowed Allowed
5.0
Allowed Allowed
5.0
Allowed Allowed
5.0
Allowed Allowed
00
Not
Not
00
Not
Not
Not
Not
00
100.
Allowed Allowed
100.
Allowed Allowed
100.
Allowed Allowed
100.
Allowed Allowed
100.
Allowed Allowed
00
Not
Allowed
0.50
Not
Allowed
0.0
Not
Allowed
20.
Not
Allowed
0.5
Not
Allowed
01
Not
Allowed
0.
Not
Allowed
0.0
Not
Allowed
Not
Not
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.00
Not
Allowed
0.50
Not
Allowed
0.00
Not
Allowed
0.50
Not
Allowed
0.00
Not
Allowed
0.50
Not
Allowed
0.00
Not
Allowed
0.0
Not
Allowed
00
Not
Allowed
1.0
Allowed Allowed
1.0
Allowed Allowed
0.00
Allowed Allowed
1.00
Not
Allowed
00
Not
Allowed
00
Not
Allowed
0.00
Not
Allowed
00
Not
Allowed