Axis Of Motion Axisx_Ctrl, Axisx_Run, Axisx_Seek, And Axisx_Man Example - Siemens Simatic S7 Series System Manual

Hide thumbs Also See for Simatic S7 Series:
Table of Contents

Advertisement

12.8.2
Axis of Motion AXISx_CTRL, AXISx_RUN, AXISx_SEEK, and AXISx_MAN
example
This program provides an example of the AXISx_CTRL, AXISx_RUN, AXISx_RSEEK, and
AXISx_MAN subroutines. You must configure the RP seek mode and a motion profile.
Table 12- 34 Example: Axis of Motion AXISx_CTRL, AXISx_RUN, AXISx_SEEK, and AXISx_MAN subroutines application
LAD/FBD
Network 1
Network 2
Network 3
S7-200 SMART
System Manual, 09/2015, A5E03822230-AC
12.8 Axis of Motion example programs
Description
Enable the axis by turning
CPU_Input1 off.
Symbol and Address:
1
Always_On = SM0.0
AXIS0_CTRL = SBR1
CPU_Input1 = I0.1
Move the axis to a known
position using the Jog
command. You can now
move the axis manually.
Symbol and Address:
1
AXIS0_MAN = SBR2
CPU_Input10 = I1.2
CPU_Input12 = I1.4
CPU_Input13 = I1.5
CPU_Input8 = I1.0
CPU_Input9 = I1.1
Reset the process. Set the
initial step to "0".
Symbol and Address:
1
CPU_Input1 = I0.1
CPU_Output3 = Q0.3
First_Scan_On = SM0.1
Homing_Done = M1.1
State_Machine_Step =
VB1500
Open loop motion control
STL
LD Always_On
= L60.0
LDN CPU_Input1
= L63.7
LD L60.0
CALL AXIS0_CTRL,
L63.7, M1.0,
VB900, VD902,
VD906, V910.0
LD CPU_Input8
AN M0.0
= L60.0
LD CPU_Input9
= L63.7
LD CPU_Input10
= L63.6
LD CPU_Input12
= L63.5
LD L60.0
CALL AXIS0_MAN,
L63.7, L63.6,
L63.5, 100000.0,
CPU_Input13,
VB920, VD902,
VD906, V910.0
LD CPU_Input1
O First_Scan_On
R M0.0, 1
MOVB 0,
State_Machine_
Step
R CPU_Output3, 3
R Homing_Done, 2
531