Siemens Simatic S7 Series System Manual page 532

Hide thumbs Also See for Simatic S7 Series:
Table of Contents

Advertisement

Open loop motion control
12.8 Axis of Motion example programs
LAD/FBD
Network 4
Network 5
Network 6
Network 7
532
Description
Start the process. When
CPU_Input0 is toggled from
off to on, the
State_Machine_Step is set
to "1".
Symbol and Address:
1
CPU_Input0 = I0.0
State_Machine_Step =
VB1500
This network turns
CPU_Input1 on.
Symbol and Address:
1
CPU_Input1 = I0.1
When the homing is com-
plete, move to the next
step.
Symbol and Address:
1
CPU_Output3 = Q0.3
Homing_Done = M1.1
Homing_Error = VB930
State_Machine_Step =
VB1500
When the state machine is
in Step 1, the system auto-
matically homes the axis. If
there is a Homing error, the
Homing_Error output dis-
plays the error code.
Symbol and Address:
1
Always_On = SM0.0
AXIS0_RSEEK = SBR5
Homing_Done = M1.1
Homing_Error = VB930
State_Machine_Step =
VB1500
System Manual, 09/2015, A5E03822230-AC
STL
LD CPU_Input0
EU
S M0.0, 2
MOVB 1,
State_Machine_
Step
LD M0.0
= CPU_Input1
LD Homing_Done
AB= Homing_Error
S CPU_Output3
MOVB 2,
State_Machine_
Step
LD Always_On
= L60.0
LDB
State_Machine_
Step, 1
EU
= L63.7
LD L60.0
CALL
AXIS0_RSEEK,
L63.7,
Homing_Done,
Homing_Error
S7-200 SMART

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s7-200 smart series

Table of Contents