Program instructions
7.7 Pulse output
During the acceleration portion of the output profile, the output wave form should reach
maximum pulse frequency in approximately 200 pulses. The output wave form should
complete the deceleration portion of the profile in approximately 400 pulses.
The following table lists the values for generating the example waveform. The profile table,
for this example, is in V memory and starts at VB500. You can use any block of V memory
that is available for a PTO profile table. You can include instructions in your program to load
these values into V memory, or you can define the values of the profile in the data block.
Table 7- 12
Address
VB500
VD501
VD505
VD509
VD513
VD517
VD521
VD525
VD529
VD533
The PTO generator begins by running Segment 1. After the PTO generator reaches the
required number of pulses for Segment 1, it automatically loads Segment 2. This continues
until the last segment. After the number of pulses for the last segment is reached, the
S7-200 SMART CPU disables the PTO generator.
For each segment of the PTO profile, the pulse train begins at the starting frequency
assigned in the table. The PTO generator increases or decreases the frequency at a
constant rate to achieve the ending frequency with the correct number of pulses. However,
the PTO generator limits the frequency to the starting and ending frequencies specified in
the table.
256
Segment 1: 200 pulses
Segment 2: 3400 pulses
Segment 3: 400 pulses
Profile table values
Value
3
Total number of segments
2,000
Starting frequency (Hz)
10,000
Ending frequency (Hz)
200
Number of pulses
10,000
Starting frequency (Hz)
10,000
Ending frequency (Hz)
3,400
Number of pulses
10,000
Starting frequency (Hz)
2,000
Ending frequency (Hz)
400
Number of pulses
Description
Segment 1
Segment 2
Segment 3