Table 12- 46 Profile detail for Mode 8 (Two-speed, continuous positive rotation) and Mode 9 (Two-
Byte offset
from start of
Table 12- 47 Profile detail for Mode 10 (Two-speed, continuous positive rotation with triggered stop)
Byte offset
from start of
S7-200 SMART
System Manual, 09/2015, A5E03822230-AC
speed, continuous negative rotation)
Step
number
profile
+0
+1
+2
0
+6
+10
1
+14
and Mode 11 (Two-speed, continuous negative rotation with triggered stop)
Step
number
profile
+0
+1
+2
0
+6
+10
1
+14
Name
Field size
STEPS
byte
MODE
byte
POS
dint/fp
SPEED
dint/fp
POS
dint/fp
SPEED
dint/fp
Name
Field size
STEPS
byte
MODE
byte
POS
dint/fp
SPEED
dint/fp
POS
dint/fp
SPEED
dint/fp
Open loop motion control
12.10 Advanced topics
Value
2
8 = Two-speed, continuous positive rota-
tion or
9 = Two-speed, continuous negative rota-
tion
n.a. (must be set to 0)
Target speed if RPS signal is inactive
n.a. (must be set to 0)
Target speed if RPS signal is active
Value
2
10 = Two-speed, continuous positive
rotation with triggered stop or
11 = Two-speed, continuous negative
rotation with triggered stop
Distance to travel after activation of TRIG
signal (value must be positive)
Target speed if RPS signal is inactive
n.a. (must be set to 0)
Target speed if RPS signal is active
555