X21/X22 Ep Terminals/Temperature Sensor Connection Motor Module; X200-X203 Drive-Cliq Interface - Siemens SINAMICS Series Equipment Manual

Booksize power modules
Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Motor Modules Booksize
4.3 Motor Module with external air cooling
4.3.3.4

X21/X22 EP terminals/temperature sensor connection motor module

Table 4-14
Terminal block X21/X22
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Type: Screw terminal 1 (see Connection Methods)
Notice
The KTY temperature sensor/the PTC must be connected with the correct polarity.
Note
The temperature sensor connection is required for motors whose temperature value is not
transmitted by DRIVE-CLiQ.
To operate, 24 V DC must be applied to terminal 3 and terminal 4 must be grounded if the
"Safe Standstill" function is selected. Upon removal, pulse inhibit is activated.
4.3.3.5

X200-X203 DRIVE-CLiQ interface

Table 4-15
DRIVE-CLiQ interface X200-X202: Single Motor Module
DRIVE-CLiQ interface X200-X203: Double Motor Module
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
4-30
Function
+Temp
-Temp
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
2
Name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
Technical specifications
Temperature sensor connection KTY84–1C130/PTC
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Isolated input
Signal propagation times:
L → H 100 μs
H → L: 1000 μs
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronic ground
Equipment Manuel for Booksize Power Modules
Manual, (GH2), Edition 06.2005, 6SL3097-2AC00-0BP2