Arrangement Of Components And Devices; General; Drive Line-Up - Siemens SINAMICS Series Equipment Manual

Booksize power modules
Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Cabinet Configuration and EMC Booksize

7.4 Arrangement of components and devices

7.4
Arrangement of components and devices
7.4
7.4.1

General

The arrangement of the components and equipment takes account of
• Space requirements
• Cable routing
• Bending radius of connection cables
• Heat dissipation
• EMC
Components are usually located centrally in a cabinet.
7.4.2

Drive line-up

Due to the current carrying capacity of the DC link busbars and their function, the
components must be arranged according to the following rule. From left to right:
• Line Module
• Motor Modules in order of power from the highest power to the lowest power
• DC link components (e.g. Braking Module, Control Supply Module, Capacitor Module)
7-14
For MOTION-CONNECT cables, see catalog D21.1 or D21.2.