7) During automatic tuning execution
The progression state can be confirmed with D22-0.
(F o r V 2 4 -O P 1 )
8) Normal completion of automatic tuning
When the automatic tuning ends normally, the "LCL" LED will change from a flicker to a stable
light. The "RUN" LED will change from a stable light to the OFF state.
Refer to section 4-5 for the adjustment items.
9) Abnormal completion of automatic tuning
If automatic tuning ends abnormally, the "FLT" LED will turn ON and a message will appear.
Investigate and check according to the error codes.
Refer to section 4-6-2 for details on the error codes.
4-6-2 Automatic tuning error messages
If automatic tuning ends abnormally, the following message will appear. Investigate and confirm the
state following the error code.
E00:ATT-n (for U30 V24OP1),
No.
n=1
The motor may not be connected correctly.
Check the connection.
The B00 and B01 parameters may not be set correctly.
Check the parameter setting.
n=2
The B00 and B01 parameters may not be set correctly.
Check the parameter setting.
n=3
The load and machine may not be separated.
Separate the load and machine.
Lengthen the acceleration time (A01-0).
Lengthen the deceleration time (A01-1).
If the motor vibrates, adjust the torque stabilizing gain (B18-2).
Normally, the default value (1.00) is set, but increase the setting value in increments of
approx. 0.05 according to the state of hunting. Please return to regulated value (1.00) of a
set value once, and reduce it by carving about 0.05 when the hunting phenomenon is not
controlled even in case of maximum value (4.00) .
n=4
The load and machine may not be separated.
Separate the load and machine.
If the motor vibrates, increase the torque stabilizing gain (B18-2).
Normally, the default value (1.00) is set, but increase the setting value in increments of
approx. 0.05 according to the state of hunting. Please return to regulated value (1.00) of a
set value once, and reduce it by carving about 0.05 when the hunting phenomenon is not
controlled even in case of maximum value (4.00) .
n=5
When the motor does not stop
Increase the acceleration/deceleration time (A01-0, A01-1).
When the motor does stop
The B00 and B01 parameters may not be set correctly.
Check the parameter setting.
n=6
The B00 and B01 parameters may not be set correctly.
Check the parameter setting.
Indicates that the output voltage did not stabilize for 1 second or more during magnetic pole
n=8
position estimation for the PM motor.
n=9
Indicates that the PM motor magnetic pole estimation did not end normally even after
retrying three times.
(F o r V 2 4 -O P 2 )
(for U30 V24OP2) n:Automatic tuning step
Cause and remedy
EN-23
U p p e r le ve l :T h e ste p s re q u ire d fo r tu n in g a re
in d ica te d (lit).
L o w e r le ve l :T h e fin is h e d s te p s a re in d ic a te d (lit).
T h e s te p c u rre n tly b e in g e xe c u te d is
in d ica te d w ith a flic k e r.