Memory Operation
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones
Address
Setting
11F4
04B0
11F5
0000
11F6
03E8
11F7
0000
11F8
03E8
11F9
0000
11FA
03E8
11FB
0000
Note Addresses other than the above should be set to their default settings (0).
The origin search acceleration and deceleration times will be used for accelera-
tion and deceleration and so this data needs to be set completely to the default
settings (0).
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Contents of setting
Position #0
1,200 pulses (4B0 Hex)
,
p
Position #1
1,000 pulses (3E8 Hex)
,
p
Position #2
1,000 pulses (3E8 Hex)
,
p
Position #3
1,000 pulses (3E8 Hex)
,
p
Section
10-2
(
)
(
)
(
)
(
)
239