Outline; Feature - Hitachi HIDIC EH-150 Applications Manual

Programable controller; ethernet module(eh-eth)
Hide thumbs Also See for HIDIC EH-150:
Table of Contents

Advertisement

1.2

Outline

This product supports production control and system operation monitor, equipment monitor and maintenance by
connecting PLC to information network.
1.
EH-ETH (This after called this module) can be mounted onto the basic base of EH-150 system and is the
communication module can be connected EH-150 system to Ethernet based on IEEE802.3.
2.
This module connected to Ethernet will operate as one of the station of the network system. For this operation this
module can exchange the data with personal computer or engineering workstation connected with network.
1.3

Feature

1. The data sending or receiving connection can be used 10 at once.
- 6 connections for automatic send/receive and 4 connections for H-series protocol (Taskcode communication) can
be used.
- Sending data and receiving data can be done with one connection.
- It is selectable TCP/IP or UDP/IP as the communication protocol for each connection.
- The maximum sending or receiving data size between PLC and PLC or PLC and host computer is 1,454 bytes.
ASR is omission of Automatic Sending/Receiving.
When you use cyclic transmission function and automatic transmission function of ASR, you can transmit/receive
a data without making a ladder(user) program.
Task code communication is original communication protocol for H-series. You can make monitoring system or
data logging system by connecting SCADA system which supports its protocol.
2. Saving the developing power with using Web server function for set-up and Automatic sending/receiving
function.
- The all configuration for communication can be done with using Web browser before to start communication.
The configured data for communication can be saved with text format file.
- It is possible to save the development power for communication program using Ladder diagram can be saved with
using the automatic sending /receiving function.
3. Using programming software called LADDER EDITOR for Windows® via Ethernet communication line.
- It is possible to monitor the I/O data or to handle the program of PLC with LADDER EDITOR for Windows® via
Ethernet communication line. You can save the time and cost for maintenance of user program or total system.
Personal computer(PC)
EH-150
EH-150
EH-150
EH-150
POWER
POWER
POWER
POWER
EH-150 System
1-2
Server machine
0
1
2
3
0
1
2
3
4
5
6
7
4
5
6
7
Tx
H.ERR
POW
8
9
10
11
8
9
10
11
Rx
C.ERR
12
13
14
15
12
13
14
15
Chapter 1 Introduction
Ethernet

Advertisement

Table of Contents
loading

Table of Contents