Electrical Connection - Pepperl+Fuchs PGV...-F200...-R4-V19 Series Manual

Incident light positioning system
Table of Contents

Advertisement

PGV...-F200/-F200A...-R4-V19
Installation
3.3

Electrical Connection

The read head is connected electrically via an 8-pin M12 x 1 connector on the side of the
housing. The power is supplied via this connection. The configurable inputs and outputs on the
read head are also located at this connection.
1
2
3
4
5
6
7
8
Figure 3.23
Connector Assignment
Main
1
8
7
2
3
5
4
Figure 3.24
Color assignment
Pepperl+Fuchs female cordsets are manufactured in accordance with EN60947-5-2. When
using a type V19-... () female cordset with an open cable end on the Main connection, the
colors are assigned as follows:
Connection pin
30
INPUT_SELECTION_DIR_RIGHT
+ UB
Data+ / TX / 485+
Data- / RX / 485-
OUTPUT_LANE_PRESENT
INPUT_SELECTION_DIR_LEFT
- UB
IN/OUT 3
6
1
2
3
4
5
6
7
8
Strand color
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
Color abbreviation
WH
BN
GN
YE
GY
PK
BU
RD