Following Error Monitoring - Siemens SINAMICS G120 Function Manual

Low-voltage inverter; basic positioner (epos) for cu250-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Basic positioner
3.4 Commissioning
3.4.5.2

Following error monitoring

Description
The following error is the deviation between the position setpoint and the position actual
value while the converter is positioning the axis.
Figure 3-8
The converter reports fault F07452 if the following error is too high. If you set the tolerance
to 0, monitoring is deactivated.
Setting following error monitoring
Precondition
You have selected the "Monitoring" screen and the "Following error monitoring" tab.
50
Monitoring the following error
Function Manual, 04/2015, FW V4.7 SP3, A5E34257659B AB
Basic positioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics series

Table of Contents