Siemens SINAMICS G120 Function Manual page 49

Low-voltage inverter; basic positioner (epos) for cu250-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Setting standstill monitoring and positioning monitoring
Precondition
You have selected the "Monitoring" screen and the "Position monitoring" tab.
Procedure
To set the standstill and positioning monitoring, proceed as follows:
1. Set the required positioning accuracy.
2. Set the time within which the axis must be positioned.
3. Set the required standstill window.
The standstill window must be larger than the positioning window.
4. Set the time within which the axis must be at standstill.
5. Define the signal "Target position reached" as a message to a higher-level control.
You have now set the standstill and position monitoring.
Parameter
p2542
p2543
p2544
p2545
Basic positioner
Function Manual, 04/2015, FW V4.7 SP3, A5E34257659B AB
Meaning
Standstill window (target position ±p2542)
Standstill monitoring time
Positioning window (target position ±p2544)
Positioning monitoring time
Basic positioner
3.4 Commissioning
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics series

Table of Contents