Basic positioner
3.3 PROFIdrive interfaces
3.3.8

Status word messages

Status word messages (MELDW)
Table 3- 17
Status word for messages and interconnection with parameters in the converter
Bit
Meaning
0
0 = Ramp-function generator active
1 = Ramp-up/ramp-down completed
1
1 = Torque utilization [%] < torque threshold value 2
(p2194)
2
1 = |n_act| < speed threshold value 3 (p2161)
3
1 = |n_act| speed threshold value 2 (p2155)
4, 5
Reserved
6
1 = No motor overtemperature alarm
7
1 = No alarm, thermal power unit overload
8
1 = Speed setpoint - actual value deviation within toler-
ance t_on
9, 10
Reserved
11
1 = Controller enable
12
1 = Drive ready
13
1 = Pulses enabled
14, 15
Reserved
28
Description
The motor is presently accel-
erating or braking
Speed setpoint and actual
speed are the same.
---
---
---
The motor temperature is
within the permissible range.
The converter temperature is
within the permissible range.
Speed setpoint and actual
speed are within the permissi-
ble tolerance range p2163.
The speed controller is ena-
bled.
The converter is ready to be
switched on.
The motor is switched on.
Function Manual, 04/2015, FW V4.7 SP3, A5E34257659B AB
P No.
p2082[0] = r2199.5
p2082[1] = r2199.11
p2082[2] = r2199.0
p2082[3] = r2197.1
p2082[6] = r2135.14
p2082[7] = r2135.15
p2082[8] = r2199.4
p2082[11] = r0899.8
p2082[12] = r0899.7
p2082[13] = r0899.11