Ip Bus Clock Header (J11) - Motorola 700 Series Installation And Use Manual

Embedded controller
Table of Contents

Advertisement

Hardware Preparation

IP Bus Clock Header (J11)

2
J11 selects the speed of the IP bus clock. You can either set the IP bus
clock to 8MHz or allow it to match the the local bus clock, which is
32MHz for the MC68040. The factory configuration has a jumper
between J11 pins 1 and 2 for an 8MHz clock.
If the jumper is installed between J11 pins 2 and 3, the IP bus clock
speed is the same as that of the MC68040 bus clock, that is 32MHz,
allowing the IP module to run with a 32MHz MPU. Regardless of
the IP bus clock setting, all IP ports operate at the same speed.
The IP32 CSR bit (IP2 chip, register at offset $1D, bit 0)
!
must be set to correspond to the jumper setting. This is
cleared (0) for 8MHz, or set (1) for 32MHz. If the jumper
Caution
and the bit are not configured the same, the board may
not run properly.
J11
J11
1
2
3
1
2
3
8MHz IP Bus Clock
32MHz IP Bus Clock
(Factory configuration)
(from MPU Bus Clock)
2-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

800 seriesMvme162lx

Table of Contents