The debugger has a special feature available for reset conditions.
You activate it by pressing the
same time, releasing
seconds later.
This ''double-button reset'' feature instructs the debugger to use the
default setup/operation parameters in ROM versus your
setup/operation parameters in NVRAM. You can use this feature
in the event your setup/operation parameters are corrupted or do
not meet a sanity check. Refer to the
for the ROM defaults.

Reset

Pressing and releasing the MVME162LX front panel
initiates a system reset. COLD and WARM reset modes are
available. By default, 162Bug is in COLD mode. During COLD
resets, a total system initialization takes place, as if the
MVME162LX had just been powered up. All static variables
(including disk device and controller parameters) are restored to
their default states. The breakpoint table and offset registers are
cleared. The target registers are invalidated. Input and output
character queues are cleared. Onboard devices (timer, serial ports,
etc.) are reset, and the two serial ports are reconfigured to their
default state.
During WARM resets, the 162Bug variables and tables are
preserved, as well as the target state registers and breakpoints.
Reset must be used if the processor ever halts, or if the 162Bug
environment is ever lost (vector table is destroyed, stack corrupted,
etc.).

Abort

The Abort function is invoked by pressing and releasing the
switch on the MVME162LX front panel. Whenever abort is invoked
when executing a user program (running target code), a snapshot
of the processor state is captured and stored in the target registers.
and
RESET
first, then releasing
RESET
ENV
Restarting the System
switches at the
ABORT
seven
ABORT
command (Appendix A)
switch
RESET
ABORT
3