4.3

Configuration - valve selection

You select the method of entering valve data under "Valve selection".
Note
There is no data in this list in the factory setting. However, you can import valve lists (e.g.
from 840D Powerline); see Chapter "Importing valve lists (Page 78)".
Figure 4-2
For the "Select valve from list" option, the selection list for valve configuration is displayed.
Select the appropriate valve. The valve data are transferred. The "Valve data" dialog box is
skipped.
For the "Enter valve data" option, the selection list to configure a valve is not displayed. The
valve selection list is displayed again if you activate the checkbox "Template from list". You
can preassign the data of the selected valve in the "Valve data" dialog.
Using the combo box "Search" you can restrict the drop-down list of valves using a free text
filter. While entering a search text, the list is updated with each keystroke. The combo box
contains such texts previously used.
Using the "Manipulated variable inversion" option, you can invert the output voltage of the
hydraulic module. The output voltage of the hydraulic module is the input voltage of the
valve.
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Configuration - valve selection
Commissioning
4.3 Configuration - valve selection
55