1.2

Recommended Cable Type and Permissible Length Cable

Reference
1
2

Check Point during Installation

1 Requires thicker wire if you connect the reader with high current consumption.
Check Point during Installation
Description
Controller Power (DC12V)
DC Power → Controller
Reader (Power and Data)
RFK505 → Controller
Door Contact
Exit Button
Sensor Input
Input → Controller
Door Lock, Alarm Device
Lock (Alarm) → Controller
RS232 Cable
Converter → Host P.C.
RS485 Cable
Controller → Converter
Controller → Controller
Controller → RFK505
RFK505 → RFK505
RFK505 → Converter
RS422 Cable
Controller → Converter
Controller → Controller
Controller→ RFK505
RFK505 → RFK505
RFK505 → Converter
Cable Specification
Belden #9409, 18 AWG
2 conductor, unshielded
Belden #9512, 22 AWG
4 conductor, shielded
Belden #9514, 22 AWG
8 conductor, shielded
Belden #9512, 22 AWG
4 conductor, shielded
Belden #9514, 22 AWG
8 conductor, shielded
Belden #9409, 18AWG
2 conductor, unshielded
Belden #9829, 24 AWG
2-twisted pair, shielded
Belden #9829, 24 AWG
2-twisted pair, shielded
Belden #9830, 24 AWG
3-twisted pair, shielded
Maximum Distance
30m
150m
300m
300m
15m
1,200m