3. Cable Color

Main Power(DC+12V)
Power Ground(GND)
HOLD Loop INPUT
BARGATE output (a transistor output) that directly controls a car circuit breaker is used for
1.
circuit breaker control relay operation. The maximum current drain rate is 1 Amps.
HOLD input is used to force NEO RF245 to read a tag when loop sensor detects any
2.
approaching vehicle. When a vehicle is detected, NC contact should be used, and the input
should also be disconnected from GND completely. In OTR mode, the reader will only output
tag ID (1 time).
CAUTION: Nothing should be connected to this input unless loop sensor is in use.
OTR cable (yellow) is used to limit the reading time to 1 (OTR = One time reading).
3.
When BOOT_INPUT is connected to GND during firmware upgrade, the system changes into
4.
applicable mode.
CAUTION: Nothing should be connected to this input during normal operation.
FFQG112S
Cable name
Wiegand Data-0
Wiegand Data-1
1)
BARGATE
2)
3)
OTR INPUT
RS232_TX
RS232_RX
4)
BOOT_INPUT
Quick Installation Guide
Color
Red
Black
Green
White
Gray
Blue
Yellow
Purple
Brown
Orange