6. The screen will display ".". Press the mode button. The screen shows the
current Zero Range setting in flashing mode. The flashing digit may be incremented
by pressing the Lb/Kg button or decremented by pressing the ZERO button. Zero
range is the percentage the zero can move from the original zero point acquired at
calibration. The zero button will not operate if outside the zero range. When outside
the zero range, the screen will display ".". The error icon will also be
displayed if the zero range is set to 1, 2 or 3. If settings 4 through 6 are selected,
the zero button will not function when attempting to zero the scale outside the
range. When the desired zero range number is selected (0=off, 1=1%, 2=2%,
3=5%, 4=1%, 5=2%, 6=5%), press the Mode button.
7. The screen displays "G". Press the mode button. The display shows the current
Graduation Size setting in flashing mode. Press either the Lb/Kg or the ZERO
buttons to cycle through the graduation options. When the desired graduation
setting is displayed (grad options 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100,
200, 500 or 500) press the Mode button.
After completing Step 7, the screen will display "" for approximately 1 second and
then advance to "".