2. The screen will display ".". Press the Mode button. The flashing display
shows the current setting. Press either the ZERO button or the lb/kg button to
toggle through Auto, on and off. When "Auto" is elected (default), the backlight
will automatically light up when low level light conditions are detected. When the
desired setting is entered, press the MODE button to continue through the mode
menu.
3. The screen will show "". Press the Mode button. The screen will display
the current setting. When the weight displayed is equal to or greater than the set
point, the corresponding icon is shown on the LCD. During normal weighing
mode, the S1 icon on the display will light when the weight is greater than or
equal to set point 1. The flashing digit may be incremented by pressing the Lb/Kg
button or decremented by pressing the ZERO button. To move one digit to the
left, press the TARE button. When the desired number is displayed, press the
mode button to continue through the mode menu.
4. The screen will display "". Press the Mode button. The display shows the
current setting. During normal weighing mode, the S2 icon on the display will
light when the weight is greater than or equal to set point 2. The flashing digit
may be incremented by pressing the Lb/Kg button or decremented by pressing
the ZERO button. To move one digit to the left, press the TARE button. When
the desired number is displayed, press the mode button to continue through the
mode menu.
5. The screen will display ".". Press the Mode button. The screen displays the
current setting. The number indicates the number of readings will be averaged
together before the reading is sent to the display. Higher values will result in a
more stable reading, but take longer to display the final value. The scale updates
at 4Hz, so an Average Rate of "8" equates to 2 seconds of averaging. Enter "1"
to disable the averaging function. The flashing digit may be incremented by
pressing the Lb/Kg button or decremented by pressing the ZERO button. To
move one digit to the left, press the TARE button. When the screen displays the
desired number, press the mode button to continue through the mode menu.
6. The screen will display ".". Press the Mode button. The screen displays the
current Average Threshold setting. This setting enables dynamic averaging,
which can improve the settling time of a large Average Rate. If the scale senses
a large weight change, it will temporarily suspend averaging, jump to the new
weight, and resume averaging. Enter a value of 1-10000 to set the threshold (in
display divisions) at which point the dynamic averaging triggers. Enter "0" to
disable dynamic averaging. The flashing digit may be incremented by pressing
the Lb/Kg button or decremented by pressing the ZERO button. To move one
digit to the left, press the TARE button. When the display shows the desired
number, press the mode button to continue through the mode menu.