Key Tare (Ir Remote Only); Peak (Ir Remote Only) - Intercomp CS750 User Manual

Crane scale
Hide thumbs Also See for CS750:
Table of Contents

Advertisement

CS750 User Manual
Rev E, April 2018

KEY TARE (IR Remote Only)

Pressing the KEY TARE key on the IR remote will allow the user to enter the TARE
weight using the keypad on the IR remote. After entering the number, press ENTER on
the IR remote to apply the new TARE. Note that the entered TARE weight must match
the grad setting for the scale. For example, if the display graduations are set to "2 lb" on
the scale, a TARE entry of "19 lb" will not accepted. In this case enter either a 18 or 20
lb setting. If an invalid TARE weight is entered the scale will blink "." 3 times and
return to normal weighing without applying the new TARE.

PEAK (IR Remote Only)

Press the PEAK key on the IR remote to enter peak mode. Press NORMAL on the IR
remote to turn peak mode off. When peak mode is enabled, the scale will show the
highest weight that has been applied to the scale since it was turned on or zeroed.
Toggling peak mode will not clear the peak weight. Press ZERO to reset the peak
weight. Peak mode works with gross or net weights and with print tickets. Continuous
print output functions only when in Gross mode.