SPECIFICATIONS

Voltage
Display
Operating Temperature
Storage Temperature
Dimensions
Weight
Pulse and Relays
Pulse Electrical
Relay Electrical
Pulse/Unit Volume (Totalizer)
Setpoint (Alarm)
Optional Analog Output
USB Communication
RS-485 Communication
Accessories

ORDERING MATRIX

Series
Option - Analog Output, RS485 (BACnet / Modbus), and USB
Option - Mounting
Control. Manage. Optimize.
DATA INDUSTRIAL is a regisitered trademark of Badger Meter, Inc . Other trademarks appearing in this document are the property of their respective entities . Due to continuous
research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an
outstanding contractual obligation exists . © 2017 Badger Meter, Inc . All rights reserved .
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0
Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412
Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11
12...24V DC / AC (Limit: 8...35V DC) (Limit: 8...28V AC)
16 character by two line alphanumeric dot matrix 7 .95 mm high backlit LCD
–20...70° C
–30...80° C
Panel mountE:
3 .78 in . W × 3 .78 in . H × 3 .23 in . D
(96 mm × 96 mm × 63 mm)
Panel mountE: 12 oz
Both pulse and relay are fully functional as either totalizing or setpoint outputs
1 Amp @ 35V DC/
Solid-state Form A
30V AC
Resistive loadE: 5Amp
Mechanical Form C
@ 120V AC/30V DC
UnitsE:
Driving sourceE:
Any predefined or custom
Flow total; Btu total
unit
Driving sourceE:
flow rate; Btu rate; temperature 1;
temperature 2, delta T
Delay to setE: 1...9999 Seconds
Driving sourceE:
Flow rate; PID control
Provides complete access to all programming and operation features
RequirementsE: USB 2 .0 A to Mini-B 5-Pin Cable (Example: SYSONIC model UAM56 GWT/B)
Supports Modbus and BACnet/MSTP
Wall mount kit
Flow Monitor
Portable Battery Operated Kit
No Option
Analog Output, RS485 with BACnet and Modbus, and USB
Panel Mount
Wall Mount
DC current draw (~280 mA)
AC power rating (~5V A)
Wall mountE:
4 .80 in . W × 4 .72 in . H × 3 .63 in . D
(120 mm × 120 mm × 92 mm)
ClosedE: 0 .5 Ω @ 1 AMP
OpenE: >10
Inductive loadE: 1Amp @ 120V AC/30V DC
RateE:
Pulse per
1 .0000000...99999999
units
UnitsE:
SetpointE:
Any predefined or custom
Pulse per 1 .0000000...99999999 units
unit
Release pointE:
Delay to releaseE:
1 .0000000...999999999
1...9999 seconds
RangeE:
SinkingE:
4...20 mA;
30V DC @ 0 mA maximum;
0...20 mA (isolated
3V @ 20 mA minimum
current sinking or
SourcingE: 600 W maximum load
sourcing)
Example:
3000
3000
3020
8
Contact timeE:
Max Pulse RateE:
1...9999 mS
1 Pulse/2 Sec
-
x
x
0
1
0
1