Figure 19 - Pdr8000 Dedicated Status Leds Definition - Futurecom PDR8000 Deployment Manual

Portable digital repeater
Hide thumbs Also See for PDR8000:
Table of Contents

Advertisement

Dedicated Status LEDs
The following table contains the state definitions for Dedicated Status LEDs.
Label
V.24 TX
V.24 TX
V.24 TX
V.24 TX
V.24 RX
V.24 RX
V.24 RX
V.24 RX
LOCAL RPT
LOCAL RPT
DC BATTERY
DC BATTERY
DC BATTERY
DC BATTERY
RF TX
RF TX
RF RX
RF RX
PDR STATUS
PDR STATUS
PDR STATUS
POWER
POWER
Figure 19 – PDR8000 Dedicated Status LEDs Definition
If the PDR8000 does not successfully power up, the fan will not start running and there will be
no lights displayed on the LED light panel. Disconnect the power source and replace the
appropriate fuse.
DC Power- the DC fuses are located inside the PDR8000. Contact Futurecom for service:
1-800-701-9180 or support@futurecom.com
State
OFF
BLINK PULSE
STEADY
BLINK FAST
OFF
BLINK PULSE
STEADY
BLINK FAST
OFF
STEADY
OFF
BLINK FAST
STEADY
BLINK SLOW
Warning, DC source approaching lower threshold
OFF
STDY
OFF
STDY
BLINK FAST
BLINK SLOW
BLINK PULSE
OFF
STEADY
PDR8000 Portable Digital Repeater Deployment Guide
Status Description
V.24 Tx Interface Off
V.24 Tx Interface Working
V.24 Tx Interface Activity
V.24 Tx Interface Failure (see Tech Log)
V.24 Rx Interface Off
V.24 Rx Interface Working
V.24 Rx Interface Activity
V.24 Rx Interface Failure (see Tech Log)
Local Repeat disabled
Local Repeat enabled
DC source below threshold
DC source above threshold
DC power acceptable
Transmitter Inactive
Transmitter Active
Receiver Inactive
Receiver Active
Error (Check Tech Log)
Warning (Check Tech Log)
PDR Functional
PDR Power Off
PDR Power On
Document 8K088X03 R3.0
Page 16 of 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PDR8000 and is the answer not in the manual?

Table of Contents