Removing And Installing Circulation Pump - Bosch SRU53E05AU Repair Instructions

Table of Contents

Advertisement

6.5

Removing and installing circulation pump

6.5.1
Removal
Remove side panels and base plate
Loosen connection between stainless steel container and plastic
base pan, (2 screws at front and 2 screws at rear)
Place appliance on its rear panel
Fold down the base pan
Using a screwdriver, press the clip on the right side of the
circulation pump inwards
Rotate pump to the right
Remove pump.
815_58300000120057_ara_en_d.doc – 25.05.11
6.5.2
Installation
Prior to installation, lubricate the seal with washing-up liquid.
Connect pump to the pump housing
Leaks
Ensure that all 4 locking hooks in the pump housing
are attached
Sluggish or blocked fan impeller
When the pump is changed, the spacer ring attached
to the motor shaft must be transferred to the new
pump
Rotate pump to the left into the pump housing until the clip
engages
Fold up the base pan and install appliance
Screw stainless steel container to the base pan
Screw on base plate and side panels
6.5.3
Removing the slide ring seal
Remove circulation pump
Loosen fan impeller, locking the rotor with a pen or screwdriver
Remove pump housing
Remove slide ring seal