Energy counters

7.2 Preset and apply start values for energy and overflow counters

Name of the user data variant
EE@Industry measurement data profile E2
(Page 219)
Basic variables for phase-specific meas-
urement L1 (Page 220)
Basic variables for phase-specific meas-
urement L1a (Page 221)
Basic variables for phase-specific meas-
urement L2 (Page 222)
Basic variables for phase-specific meas-
urement L2a (Page 223)
Basic variables for phase-specific meas-
urement L3 (Page 224)
Basic variables for phase-specific meas-
urement L3a (Page 225)
User-defined user data variant
7.2
Preset and apply start values for energy and overflow counters
At the beginning of a new work order, it may be useful to start the energy and overflow
counter with new start values.
Define the new start values for the energy and overflow counter in data record DS 143.
Note
Pre-set start values for counters
If you have not yet transferred any start values to the CPU using the data record DS 143,
then start the counters with the value 0.
With all the module versions there are two ways of applying the start values:
● Transfer start values from data record DS 143 and apply them immediately
● Transfer start values from data record DS 143 and only apply them after setting a special
bit (DQ bit for counter reset)
Both options are described in the following sections.
General reset
With module versions with 20 bytes of output data you can reset the energy and overflow
counters. With a general reset, you cannot preset any start values; the start values for
energy and overflow counters are always zero with a general reset.
You can find additional information on the general reset in the section Basics for reading
measured values (Page 41).
See also
Structure for energy counters (DS 143) (Page 232)
56
Number of the
Comment
user data variant
ID 226 or E2
Measured values for total active energy L1L2L3
H
ID 159 or 9F
Measured values for phase-specific active, reactive and
H
apparent energy for phase L1
ID 158 or 9E
Measured values for phase-specific active, reactive and
H
apparent energy for phase L1
ID 157 or 9D
Measured values for phase-specific active, reactive and
H
apparent energy for Phase L2
ID 156 or 9C
Measured values for phase-specific active, reactive and
H
apparent energy for Phase L2
ID 155 or 9B
Measured values for phase-specific active, reactive and
H
apparent energy for Phase L3
ID 154 or 9A
Measured values for phase-specific active, reactive and
H
apparent energy for Phase L3
ID 1 or 01
and ID
Measured variables for energy can be selected in a
H
2 or 02
user-defined manner
H
Analog input module AI Energy Meter 480VAC/CT HF (6ES7134-6PA00-0CU0)
Manual, 07/2018, A5E42674880-AA