9.4 Calibration
Benning guarantees compliance with the technical and accuracy specifications
stated in the operating manual for the first 12 months after the delivery date.
To maintain accuracy of the measuring results, the device must be recalibrated
in regular intervals by our factory service. We recommend recalibrating the de-
vice once a year. For this purpose, send the device to the following address:
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Service Center
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protection class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Ambient conditions:
Maximum barometric height for measurements: 2000 m,
Temperature: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Use the measuring leads in perfect and clean condition as well as according
to these operating instructions only, as otherwise the protection provided
might be impaired.
-
Replace the measuring leads, if the insulation is damaged or if the conduc-
tor/connector is interrupted.
-
Do not touch the bare contact tips of the measuring leads. Only touch the
area intended for your hands!
-
Insert the bent terminals into the testing or measuring device.
11. Environmental note
At the end of product life, dispose of the unserviceable device via
appropriate collecting facilities provided in your community.
02/ 2019