Page 1
Operating manual Translation of the German original version...
Page 2
General non-discrimination Benning is aware of the importance of language with regard to the equality of men and women, and endeavours to take this into account at all times. To improve readability, we have refrained from consistently using differentiating formulations.
Device description........................... 13 Device structure ........................ 13 Functions.......................... 14 Operation.............................. 16 Requirements for measuring.................... 16 Measuring with a multimeter .................... 17 Measuring with the BENNING IT 200 installation tester ............. 17 Maintenance ............................. 18 Maintenance schedule ...................... 18 Cleaning the device...................... 18 Calibrating the device...................... 18 Technical data............................ 19 Disposal and environmental protection .................... 20 Index ................................. 21...
Page 4
Table of figures Table of figures Figure 1 BENNING CC 4-1 / CC 4-2 device structure ................BENNING CC 4-1 / CC 4-2 5186 / 07/2021 en...
Page 5
Symbols used in the operating manual..................Table 4 Electrical specifications........................ Table 5 Measuring accuracy (BENNING CC 4‑1)..................Table 6 Measuring accuracy (BENNING CC 4‑2)..................Table 7 Maintenance schedule ......................... Table 8 Technical data ..........................5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
Non-observance of this operating manual might result in product damage, property damage and/or personal injury. Benning assumes no liability for damage and malfunctions resulting from the failure to observe the instructions in this operating manual. BENNING CC 4-1 / CC 4-2...
Information in this operating manual can be changed at any time without prior notice. Benning is not obligated to make amendments to this operating manual or to keep it up to date.
The device has been built and tested in compliance with the following standards and has left the factory in perfectly safe condition. • IEC / DIN EN 61010-1 (VDE 0411‑1) • IEC / DIN EN 61010-2-030 (VDE 0411‑2‑030) • IEC / DIN EN 61010-031 (VDE 0411‑031) BENNING CC 4-1 / CC 4-2 5186 / 07/2021 en...
Symbols used in the operating manual Symbol Meaning General warning Warning of electric voltage! (AC) alternating voltage or alternating current Earth (voltage to earth) Table 3: Symbols used in the operating manual 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
– Use of components, accessories, spare or replacement parts that have not been released and approved for the respective application by Benning – Non-observance, manipulation, changes or misuse of the operating manual or the instructions and notes contained therein –...
Even low voltages from 30 V‑AC and 60 V‑DC on can be dangerous to human life! • Please observe relevant regulations on occupational safety and health. • If necessary, use appropriate protective equipment. 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
2.5 Special types of risks Scope of delivery The scope of delivery of the device includes the following components: • 1 x BENNING CC 4‑1 or BENNING CC 4‑2 current clamp adapter • 1 x operating manual BENNING CC 4-1 / CC 4-2 5186 / 07/2021 en...
2 Housing with labelling field conductor) 3 Current clamp bulge (protection against 4 Opening lever contact with conductor) 5 4 mm safety jacks 6 Connecting cable (firmly connected) 7 4 mm safety connectors 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
Device description 4.2 Functions Functions In combination with a multimeter or the BENNING IT 200 installation tester, you can use the device to carry out AC current measurements. Electrical specifications BENNING CC 4‑1 CC 4‑2 AC current ranges Nominal current 1 000 A Transformation ratio 1 000:1 (1 mA / 1 A) Output via 4 mm safety connectors via 4 mm safety jacks...
Operation 5.1 Requirements for measuring Operation You can carry out measurements using a multimeter [} page 17] or the BENNING IT 200 installation tester [} page 17] . Requirements for measuring • Please observe the operating manual of the multimeter or installation tester used (especially the safety instructions and warnings contained therein).
Requirements • Please observe the requirements for measuring [} page 16]. Procedure Carry out the measurement according to the operating manual of the BENNING IT 200 installation tester. 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
Clean the exterior of the device with a clean and dry cloth or a special cleaning cloth. Calibrating the device Benning guarantees compliance with this technical and accuracy specifications stated in this operating manual for the first 12 months after the delivery date.
85 % RH (0 … 35 °C), non-condensing, linearly decreasing for T > 35 °C Storage Ambient temperature -30 … 70 °C (Do not permanently expose the device to sunlight.) Max. relative air humidity 85 % RH (0 … 35 °C), non-condensing, linearly decreasing for T > 35 °C Table 8: Technical data 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
Disposal and environmental protection 6.3 Calibrating the device Disposal and environmental protection At the end of product life, dispose of the unserviceable device via appropriate collecting facilities provided in your community. BENNING CC 4-1 / CC 4-2 5186 / 07/2021 en...
7 Holder of rights 2 Intended use 10 Maintenance 18 Maintenance schedule 18 Manufacturer 2 Measuring With a multimeter 17 With the BENNING IT 200 installation tester 17 Non-discrimination 2 5186 / 07/2021 en BENNING CC 4-1 / CC 4-2...
Page 22
BENNING Elektrotechnik und Elektronik GmbH & Co. KG Münsterstraße 135 - 137 D - 46397 Bocholt Phone: +49 2871 93-0 Fax: +49 2871 93-429 Internet: www.benning.de E-Mail: duspol@benning.de BENNING CC 4-1 / CC 4-2 5186 / 07/2021 en...