Analog Inputs (Analog Comparators (A))

Relationship between Start and Stop Dates
Setting and operation
Start and stop
When start date is
date settings
before stop date
and operation
When start date is
after stop date
When start and
stop dates are the
same.
Note
3-9-3

Parameter Monitor Screen Display

RUN
3-10

Analog Inputs (Analog Comparators (A))

example
ON: 04/01
OFF: 09/01
ON: 12/26
OFF: 01/07
ON: 07/26
OFF: 07/26
To stop operation on August 31, set the stop date to the following
day (September 1).
Current date
Calendar timer bit status ( : OFF/ : ON)
Start date
Stop date
Two analog voltage inputs between 0 and 10 V can be incorporated
into the CPU Units with a DC power supply. I4 and I5 for CPU Units
with 10 I/O points and Ia and Ib for CPU Units with 20 I/O points can
be used as analog voltage inputs.
The analog input signal is converted to BCD (00.0 to 10.0). The
results can be used with one of the comparators A0 to A3, and the 4
comparison outputs can be used as input conditions in the program.
Setting
Operates between 1 April and 31 August.
(See note.)
Operates between 26 December and 6
January the following year.
Operates regardless of the date.
Section 3-10
Operation
75