Safety Relay Unit G9SA The G9SA Series Offers a Complete Line-up of Compact Units. • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Page 3
None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting time) None: No OFF-delay T075: 7.5 seconds T15: 15 seconds T30: 30 seconds http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 4
5. The durability is for an ambient temperature of 15 to 35 C and an ambient humidity of 25% to 75%. 6. Weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 5
KM1 and KM2: Magnetic Contactor KM3: G3J Solid-state Contactor (G3J) 3-phase motor Note: This circuit achieves EN954-1 Safety Category 4. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 6
KM1 and KM2: Magnetic Contactor KM3: G3J Solid-state Contactor (G3J) 3-phase motor Note: This circuit achieves EN954-1 Safety Category 4. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 7
The OFF-delay output, however, achieves EN954-1 (NC) Safety Category 3. KM1 and KM2 (NO) Operation instruction Motor rotation OFF-delay time http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 8
K1 and K2 (NO) KM3 and KM4 (NC) KM3 and KM4 (NO) Operation instruction Motor M2 rotation OFF-delay time 2 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 9
Note: 1. This circuit achieves EN954-1 Safety Category 4. (See 2. The F3SN-A auxiliary output wiring is shown for dark-ON note 2.) operation. Feedback loop Control circuit http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 10
Control circuit Note: 1. Use a 1NC+1NO switch for S11 and S12. 2. This circuit achieves EN954-1 Safety Category 4. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 11
Note: This circuit achieves EN954-1 Safety Category 4. G9SA-EX301 K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 12
2: The K1 and K2 indicators light when 13.2 the NO contacts of internal relays K1 and K2 close. R2.3 17.5 max. 111 max. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 13
4. With 24-VAC/VDC type, the power supply terminals A1 and A2 have polarities. A2 is the negative pole. Off delay timer 14 24 34 42 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 14
• EN standards, certified by BG: the EN954-1 standards when they are used as shown in the EN954-1 examples provided by OMRON. The Relays may not meet the EN60204-1 standards in some operating conditions. The OFF-delay output of EN574 (G9SA-TH301 only) models G9SA-321-T@ and EX031-T@, however, conform to Safety •...
Page 15
Fig 2 A1 A2 T11 T12 Y1 X1 − K3 K1 K3 K2 Power source PE T21 Power source http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 16
Mounting Lead Wire Diameters Design When Sockets are Used Mounting Direction When Devices Such as Microcomputers are in Proximity http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 17
• Ratings and performance values given in this catalog are for individual tests and do not indicate ratings or performance values under composite conditions. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 18
B Drive Circuits B-A-2 Combining Relays and Sockets Use OMRON Relays in combination with specified OMRON Sockets. B-B-1 Providing Power Continuously for Long Periods If the Relays are used with sockets from other manufacturers, it may cause problems, such as abnormal heating at the mating point due to If power is continuously provided to the coil for a long period, differences in power capacity and mating properties.
Page 19
Relay. Be sure to check relay suitability under actual load conditions. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 20
Relay withstand voltage value is applied, it will cause line and insulation deterioration between coils and contacts and between contacts of the same polarity. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 21
This catalog values for the must-operate voltage and must-release voltage are given for a coil temperature of 23°C. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 22
The frequency with which the inspections are needed will depend on factors such as the operating environment and the type of load. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 23
Apply gold plating or rhodium devices at the high end of the ratings can result in abnormal heating plating. and burning at connections. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 24
E-C-4 Coating and Packing G7S and G7SA Relays are not fully sealed, so do not use a coating or packing resin. C-10 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 25
Terminal length Power supply line Smoothing Relay drive transistor capacitor C-11 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 27
Continued next Note: For lead-free solder, perform the soldering under conditions that conform to the applicable specifications. page. C-13 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 28
Depending on the type of coating selected, it may damage the Relay case and chemically dissolve the seals, causing them to lose their sealing capability. C-14 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 29
If checking the circuit reveals no abnormality, and it prevented by means of careful consideration before operation and by appears that the fault is caused by a Relay, contact your OMRON selecting the correct Relays. representative. (Do not disassemble the Relay. Doing so will make it The following table shows the main faults that may occur, their impossible to identify the cause of the problem.)
Page 30
• Related International Standards: ISO 12100 Basic Concepts, General Principles for Design IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems (c)Copyright OMRON Corporation 2007 All Rights Reserved. http://www.ia.omron.com/ Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 31
Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.