Stabilizing Input Operations
Select
Other/Input
filter.
/
/
Expansion I/O Unit input
(Displayed only when Expansion
Units are connected.)
/
Note
Q6TTXPS9
8PIUS6TU
768FGDBCU
DIQVUÃADGU@S
DII@S
@YQ
@YQ!
@YQ"
CPU Unit input
DIQVUÃADGU@S
DII@S
PAA
PAA
DIQVUÃADGU@S
DII@S
PI
1.
The filter timers outlined in the following table are set for each
input type when the input filter function is set.
Input specifications
AC input
100 VAC
240 VAC
DC input
2.
The input filter settings are read when the ZEN starts opera-
tion.
Press the OK Button to display the Input Fil-
ter Settings Menu.
Use the Up and Down Buttons to select from
the menu the Unit for which the input filter is
to be set.
Press the OK Button twice to change to a
flashing cursor and enable input filter set-
tings to be made.
Use the Up/Down Buttons to switch between
ON and OFF.
Press the OK Button to confirm the setting.
Press the OK Button again to complete the
setting.
Input
filter not
used
50 ms
100 ms
15 ms
Section 4-2
Input
filter used
70 ms
120 ms
50 ms
91