Multi-Vises; Vise Pressure Control Valves; Runout Detector (Factory Option - Amada HFA-250 Operator's Manual

Horizontal bandsaw
Table of Contents

Advertisement

MULTI-VISES

VISE PRESSURE CONTROL VALVES

RUNOUT DETECTOR
A-2
Operate together with the
front and rear vises, and
clamp from above multiple
workpieces stacked in the
front and rear vises. Be
sure to use the multi-vises
when stack cutting the
workpieces.
Adjust the force with which
the front and rear vises
clamp the work. The vise
pressure control valves are
used to clamp pipes and
other workpieces likely to
deform.
Pressure adjusting range:
1.0 to 2.7 MPa {10 to 27
2
kgf/cm
, or 142 to 384 psi}
for HFA-250 and HFA-
250W,
1.1 to 3.5 MPa {11 to 35
2
kgf/cm
, or 156 to 498 psi}
for HFA-400 and HFA-
400W
A device to detect the runout of the saw blade during cutting and
automatically stop the machine when the preset runout tolerance is
exceeded.
(FACTORY OPTION)

Hide quick links: