Chapter 3 Control Examples

3-1 HL-C2 Measurement Value Loading (example)

connection to HL-C2
Number of connection= 1?
3
HLC2_OpenByIndex( )
HLC2_ExecMemInitial( )
HLC2_HeadLaserOn( )
OUT1 meas. value loading
HLC2_GetMeasureValue( )
HLC2_HeadLaserOn( )
Start
Loading of number of
HLC2_GetCount( )
Device
HL-C2 open
HL-C2 initialization
HLC2_Init( )
Memory initialization
Head A laser ON
Head A laser OFF
HL-C2 close
HLC2_Close( )
End
Error processing
HL-C2 handle is loaded by using device number.
HL-C2 is initialized by the handle that was loaded in
the previous step.
OUT1 is measured.
The data is stored into double
variables.