Outscalingmeasurevaluea; Outscalingmeasurevalueb - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

19)OutScalingMeasureValueA

IO for OUT setting [Analog scaling measurement value A]
HLC2_STATUS HLC2_OutScalingMeasureValueA (HLC2_HANDLE
hlc2Handle, DWORD dwOut, DWORD dwIO, LPDOUBLE lpdValue, BYTE
bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
LPDOUBLE lpdValue
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.

20)OutScalingMeasureValueB

IO for OUT setting [Analog scaling measurement value B]
HLC2_STATUS HLC2_OutScalingMeasureValueB (HLC2_HANDLE
hlc2Handle, DWORD dwOut, DWORD dwIO, LPDOUBLE lpdValue, BYTE
bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
LPDOUBLE lpdValue
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Chapter 2 API Function Specifications
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing analog
scaling measurement value A* of
load/setting target
* Analog scaling measurement value A
*lpdValue = -950.000000 to
Selects BCC addition
(0:BCC omit, 1:BCC add)
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing analog
scaling measurement value B* of
load/setting target
* Analog scaling measurement value B
*lpdValue = -950.000000 to
Selects BCC addition
(0:BCC omit, 1:BCC add)
2-39
+950.000000[ ㎜ ])
+950.000000[ ㎜ ])
2

Advertisement

Table of Contents
loading

Table of Contents