Chapter 2 API Function Specifications

11)OutAverageTimes

IO for OUT setting [Average times]
HLC2_STATUS HLC2_OutAverageTimes (HLC2_HANDLE hlc2Handle, DWORD
dwOut, DWORD dwIO, LPDWORD lpSelect, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
2
LPDWORD lpSelect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing average
times* of load/setting target
* Average times:
*lpSelect = 0:1 time
Selects BCC addition
(0:BCC omit, 1:BCC add)
2-34
1:2 times
2:4 times
3:8 times
4:16 times
5:32 times
6:64 times
7:128 times
8:256 times
9:512 times
10:1024 times
11:2048 times
12:4096 times
13:8192 times
14:16384 times
15:32768 times
16:65536 times