1)HeadSetupMode

IO for head setting [installation mode].
HLC2_STATUS HLC2_HeadSetupMode(HLC2_HANDLE hlc2Handle,
DWORD dwHead, DWORD dwIO, LPDWORD lpReflect, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
2
DWORD dwHead
DWORD dwIO
LPDWORD lpReflect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Handle of device
Specifies head. (HEADA or HEADB)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing installation
mode* of load/setting target
*Installation mode:
*lpReflect = 0:Diffuse
1:Specular
Selects BCC addition
(0:BCC omit, 1:BCC add)