Getalarmstate; Getstrobestate - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

31)GetAlarmState

Loads OUT setting [Alarm output status].
HLC2_STATUS HLC2_Get AlarmState (HLC2_HANDLE hlc2Handle,
DWORD dwOut, LPDWORD lpStatus, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
LPDWORD lpStatus
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.

32)GetStrobeState

Loads OUT setting [Strobe] status.
HLC2_STATUS HLC2 HLC2_GetStrobeState(HLC2_HANDLE hlc2Handle,
DWORD dwOut, LPDWORD lpStatus, BYTE bccFlg)
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
LPDWORD lpStatus
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Chapter 2 API Function Specifications
Handle of HL-C2
Specifies output. (OUT1 or OUT2)
Variable pointer for storing loaded alarm
output status*
* Readout alarm output status:
*lpStatus =
0: No alarm output status (OFF)
1: Measurement alarm output status
(ON)
6: Export controlled head connected
status (ON)
7: Head connection check error (ON)
Selects BCC addition
(0:BCC omit, 1:BCC add)
Handle of HL-C2
Specifies output. (OUT1 or OUT2)
Variable pointer for storing loaded strobe
status*
* Readout strobe status:
*lpStatus =
0: No Strobe output status(OFF)
1: Strobe output status (ON)
Selects BCC addition
(0:BCC omit, 1:BCC add)