2-2-6 Buffering Setting Command

1)BufferingMode

IO for [Buffering mode]
HLC2_STATUS HLC2_BufferingMode(HLC2_HANDLE hlc2Handle,
DWORD dwIO, LPDWORD lpSelect, BYTE bccFlg)
Argument
HLC2_HANDLE hlc2Handle
DWORD dwIO
LPDWORD lpSelect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.

2)BufferingType

IO for [Buffering type]
HLC2_STATUS HLC2_BufferingType(HLC2_HANDLE hlc2Handle,
DWORD dwIO, LPDWORD lpSelect, BYTE bccFlg)
Argument
HLC2_HANDLE hlc2Handle
DWORD dwIO
LPDWORD lpSelect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Chapter 2 API Function Specifications
Handle of device
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing buffering
mode selection* of load/setting target
* Buffering mode selection:
*lpSelect = 0: Continuous
Selects BCC addition
(0:BCC omit, 1:BCC add)
Handle of device
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing buffering
type selection* of load/setting target
* Buffering type selection:
*lpSelect = 0:OUT1&2
Selects BCC addition
(0:BCC omit, 1:BCC add)
2-59
1: Trigger
2: Timing
3: Sample Trigger
1:OUT1
2:OUT2
2