Chapter 2 API Function Specifications

5)OutZeroSet

IO for OUT setting [Zero set]
HLC2_STATUS HLC2_OutZeroSet (HLC2_HANDLE hlc2Handle, DWORD
dwOut, DWORD dwIO, LPDWORD lpSelect, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
2
LPDWORD lpSelect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.

6)OutTiming

IO for OUT setting [Timing]
HLC2_STATUS HLC2_OutTiming (HLC2_HANDLE hlc2Handle, DWORD
dwOut, DWORD dwIO, LPDWORD lpSelect, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
LPDWORD lpSelect
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing zero set*
of load/setting target.
* Zero set:
*lpSelect = 0:OFF, 1:ON
Selects BCC addition
(0:BCC omit, 1:BCC add)
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing timing* of
load/setting target.
* Timing:
*lpSelect = 0:OFF, 1:ON
Selects BCC addition
(0:BCC omit, 1:BCC add)