Out Setting (Out1/2) Command; Outpattern - Panasonic HL-C2 Series User Manual

Ultra high-speed, high-accuracy laser displacement sensor
Hide thumbs Also See for HL-C2 Series:
Table of Contents

Advertisement

2-2-3 OUT Setting (OUT1/2) Command

1)OutPattern

IO for OUT setting [Output selection]
HLC2_STATUS HLC2_OutPattern(HLC2_HANDLE hlc2Handle, DWORD
dwOut, DWORD dwIO,LPDWORD lpPattern, BYTE bccFlg);
Argument
HLC2_HANDLE hlc2Handle
DWORD dwOut
DWORD dwIO
LPDWORD lpPattern
BYTE bccFlg
Return value
Returns HLC2_OK if normal end.
Chapter 2 API Function Specifications
Handle of device
Specifies output. (OUT1 or OUT2)
Selects IO. (0: load (input), 1:setting (output))
Variable pointer for storing output
selection* of load/setting target
*Output selection
*lpPattern = 0:[A]
1:[B]
2:[-A]
3:[-B]
4:[A+B]
5:[-(A+B)]
6:[A-B]
7:[B-A]
8:[A Transparent object]
9:[B Transparent object]
10:[-A Transparent object]
11:[-B Transparent object]
12:A1+B1[Transparent
13:-(A1+B1)[Transparent
14: A1-B1[Transparent
15: B1-A1[Transparent
Selects BCC addition
(0:BCC omit, 1:BCC add)
2-27
object]
object]
object]
object]
2