Power Supply Of The Industrial Pc; Current Carrying Capacity Of The 100-240 V Power Supply Unit; Mains Socket; Power Cords Europe - Beckhoff C5240 Installation And Operating Instructions Manual

19-inch slide-in industrial pc
Hide thumbs Also See for C5240:
Table of Contents

Advertisement

3.3 Power supply of the Industrial PC

The Industrial PC is fitted with a 100-240 V/ 3 A max., 50-60 Hz full range power supply unit (with the
option of an uninterruptible power supply UPS).

3.3.1 Current carrying capacity of the 100-240 V power supply unit

Output voltages from the 100-240 V power supply unit
+3.3 V
+5 V stand by
+5 V
+12 V1
+12 V2
-12 V

3.3.2 Mains Socket

A mains socket is located at the rear of the PC housing in order to connect the power supply.
Socket at the PC housing

3.3.3 Power cords Europe

In the area Europe you use the provided cable with inlet connector for non-heating apparatus to connect
the Industrial-PC to the power supply:

3.3.4 Power cords USA / Canada

In the area USA / Canada the power supply cable must show the following specifications according to the
supply voltage:
§
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V, 10 A, Type SJT or Type
SVT; one end terminates in NEMA 5-15P/-20P grounding-type attachment plug, other end in
appliance coupler. Minimum temperature rating of supply cables should be 80 °C.
or
§
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V, 10 A, Type SJT or Type
SVT; one end terminates in NEMA 6-15P/-20P grounding-type attachment plug, other end in
appliance coupler. Minimum temperature rating of supply cables should be 80 °C.
C5240
Current loading maximum
21.0 A
2.5 A
15.0 A
11.0 A
8.0 A
0.3 A
Installation
17

Advertisement

Table of Contents
loading

Table of Contents