Daikin AT09HV2S Service Manual page 31

Removal procedure, 2.5/3.5/5.0 kw class, 9000/13000 btu/h class, indoor unit, inverter/non-inverter, wall mounted type, cooling only, heat pump
Table of Contents

Advertisement

Si04-751
Step
4
Unfasten the hook (a)
of the fan motor fixing
plate and unfasten the
hook (b).
2. Remove the fan rotor.
Slide the fan rotor to the
1
right.
2
Loosen the screw and
remove the fan motor.
Removal Procedure
Procedure
Hook (a)
Fan motor fixing
plate (upper)
Hook (a)
Hook
Fan rotor
Screw
Fan motor
Removal of Fan Rotor
Points
Hook (b)
(R4410)
Fan
motor
fixing
plate
(lower)
Hook (b)
(R4411)
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm of
play between the side face
of the rotor and the bottom
frame.
(R4412)
Side face of rotor
5 mm
(1) Insert the fan motor with
approx. 5 mm left.
(R4413)
(2) Tighten the screw until it
stops. Then turn the screw
in one scroll.
(3) Move the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
Side face of
bottom frame
(R2808)
(R9582)
29

Advertisement

Table of Contents
loading

Table of Contents