7 Commissioning Overview: Commissioning............18 Checklist before commissioning..........18 To perform a test run..............18 7.3.1 To perform a test run in winter season ....... 18 Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
WARNING Make sure installation, servicing, maintenance and repair NOTICE comply with instructions from Daikin and with applicable Works executed on the outdoor unit are best done under legislation (for example national gas regulation) and are dry weather conditions to avoid water ingress.
Page 4
26.1 39.1 27.8 41.5 29.5 44.1 31.3 46.7 33.1 49.4 34.9 52.2 55.1 36.9 58.0 38.8 7.956 61.0 7.956 7.956 40.8 Total refrigerant charge in the system Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
Make sure water quality complies with EU directive ▪ In case re-charge is required, refer to the nameplate of the unit. It 98/83 EC. states the type of refrigerant and necessary amount. (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
▪ Format: Paper (in the box of the indoor unit) ▪ Indoor unit installation manual: ▪ Installation instructions ▪ Format: Paper (in the box of the indoor unit) Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin extranet (authentication required). Installer reference guide at a...
▪ In places where the unit would be in the path of direct sunlight. on-site. ▪ In bathrooms. It contains information about: ▪ Preparing the installation site Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
(see "PS High" on the unit construction MUST comply with applicable name plate), larger piping thickness might be required. legislation. WARNING ALWAYS use multicore cable for power supply cables. (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
Result: The front panel shaft on 1 side will be disconnected. To remove the electrical wiring box cover 3 Disconnect the front panel shaft on the other side in the same manner. 1 Remove the front grille. Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
Pocket for the pipe port cover Tabs for placing a spirit level Through-the-wall hole Ø 65 mm Drain hose position Position for the tape measure at symbol " " Gas pipe end (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
(In case the interconnection cable was stripped in advance, cover the ends with insulating tape.) 7 Bend the end of the cable up. (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
2 Attach the connection cable to the S21 connector and pull the release the wireless adapter and remove it from the holder. wire harness as shown in the following figure. Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
Also read the precautions and requirements in the following chapters: 7 Press: ▪ General safety precautions Model Button ▪ Preparation FTXP-L and ATXP-L DANGER: RISK OF BURNING FTXF-A (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
Make sure the flare nut is fitted. ▪ ALWAYS use a spanner and torque wrench together to tighten the flare nut when connecting the piping. This to prevent nut cracking and leaks. Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
Do NOT connect the power supply to the indoor unit. This Interconnection cable 4-core cable ≥1.5 mm² could result in electrical shock or fire. (indoor↔outdoor) and applicable for 220~240 V (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
When operating the air conditioner in Cooling mode in winter, set it to test run operation using the following method. Checklist before commissioning Do NOT operate the system before the following checks are OK: Installer reference guide (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Daikin room air conditioner 4P513661-1 – 2017.10...
▪ Show the user what to do in relation to maintaining the unit. Disposal Dismantling of the unit and treatment of the refrigerant, oil and other parts MUST comply with the applicable legislation. (A)(F)TXP20~35L2V1B + FTXF20~71A2V1B Installer reference guide Daikin room air conditioner 4P513661-1 – 2017.10...
10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). 10.1 Wiring diagram Unified Wiring Diagram Legend For applied parts and numbering refer to the wiring diagram sticker supplied on the unit.
Page 21
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation.