6.6.
Electrostatic Discharge
The module is not protected against electrostatic discharge (ESD) in general. Consequently, it should be
subject to ESD handling precautions that are typically applied to ESD sensitive components. Proper ESD
handling and packaging procedures must be applied throughout the processing, handling and operation
of any application that incorporates the module.
The following table shows the electrostatic discharge characteristics of SC20-W module.
Table 13: ESD Characteristics (Temperature: 25° C, Humidity: 45%)
Tested Points
VBAT, GND
All Antenna Interfaces
USB Interfaces
Other Interfaces
SC20-W_Manual_R1.0
Contact Discharge
+/-5
+/-5
+/-2
+/-0.5
Confidential / Released
Air Discharge
+/-10
+/-10
+/-4
+/-1
Unit
KV
KV
KV
KV
30 /
41