If you run the update application from installer file it means that correct file with the firmware was already
loaded and „Open App. File" button is not active. If there is only one CSMIO/IP controller in network - the
application asks to start the update automatically. If there are more controllers then you should chose one
IP address from a list to update the controller you want and click „Flash Program".
CSMIO/IP-A controller is protected if update fails. There is always a possibility to try again
Before update – close Mach3 program.
If you install new firmware version but you do not update with uploader application then Mach3 program
during start will inform you about incompatibility between versions and communication will be
interrupted.

Plugin file update

Plugin is updated automatically during CSMIO/IP firmware installation.

Update verification

After firmware update is finished, you can start Mach3 again and open diagnostics window. In the bottom
bar, you should see your update firmware version.