Product Models; Technical Parameters - AEG AS-IC01-2 Series Installation Instructions Manual

Three-phase grid-tied solar inverter 12 kw to 30 kw
Hide thumbs Also See for AS-IC01-2 Series:
Table of Contents

Advertisement

13

2.3.3 Product models

Here below is an overview of the models currently available for the series AS-IC01-2 up to 30 kW. Please refer to the
specifications in 2.4 "Technical parameters". Technical specifications are subject to change without notice.
Product type
Three-phase (L1, L2, L3, N, PE)
Three-phase grid-tied solar inverter
Three-phase grid-tied solar inverter
Three-phase grid-tied solar inverter
Three-phase grid-tied solar inverter
Three-phase grid-tied solar inverter
Three-phase grid-tied solar inverter

2.4 Technical parameters

Below is an overview of the technical parameters of the product in series AS-IC01 and AS-IC01-2. Technical specifications
are subject to change without previous notice. Please refer to the related product datasheet which you can also find
under
www.aeg-industrialsolar.de
DC input
AC output
System
PD201808 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (12-30 kW) V.2-18 EN
Table 3: Current inverter models in the AEG AS-IC01-2 series up to 30 kW
> Service > Product Datasheet for the latest parameters.
Model
Max. DC voltage (V)
Starting voltage (V)
MPPT voltage(V)
180 - 800
Operation voltage (V)
350 - 800
MPPT/string per MPPT
Max. DC power (W)
Max. input current (A) x
number of MPPT
Isc PV (A)
Maximum backflow current (in-
verter backflow to PV array)
DC switch
Max output power (W)
Voltage(V)/ frequency(Hz)
Maximum output current (A)
Maximum output fault current
AC inrush current
Maximum output overcur-
rent protection (A)
Power factor
Harmonic distortion
Cooling method
Model
AS-IC01-12000-2
AS-IC01-15000-2
AS-IC01-17000-2
AS-IC01-20000-2
AS-IC01-25000-2
AS-IC01-30000-2
Three-phase inverters AS-IC01-xxx-2 (up to 30 kW)
12kW
15kW
1000
1000
200
200
180 - 800
180 - 800
400 - 800
400 - 800
2/2
12500
15600
19 x 2
21 x 2
21 x 2
23.5 x 2
25.5 x 2
0A
0A
12000
15000
320~460Vac, 50Hz(47~51.5Hz)
19.3
24.1
250A @41.6ms
Less than 10A
38.2
47.7
-0.80~+0.80(adjustable)
< 3% (rated power)
Rated output
power (W)
12000
15000
17000
20000
25000
30000
17kW
20kW
25kW
1000
1000
1000
200
300
300
280-800
280-800
450-800V
480-800V
2/3
17500
20800
26000
23 x 2
25 x 2
30 x 2
27 x 2
33 x 2
0A
0A
0A
Optional
17000
20000
25000
27.3
32
40
472A @ 11.04ms
Less than 20A
54
63.3
79.1
Air cooling
MPPT number
2
2
2
2
2
2
13
30kW
1000
300
280-800
480-800V
31200
33 x 2
36 x 2
0A
30000
48
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents