  • Page 1 AEG GRID-TIED SOLAR INVERTERS INSTALLATION MANUAL INVERTER SERIES: AS-IR02-XXX XXX= 700 / 1000 / 1500 / 2000 / 2500 / 3000 SINGLE-PHASE, 1 MPPT AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 2: Table Of Contents

    AEG GRID-TIED SOLAR INVERTERS Thank you for choosing the reliability of AEG grid-tied solar inverters! This installation manual is intended for dealers and installers involved in the planning, installation and commissioning of photovoltaic systems deploying AEG solar inverters. AEG grid-tied solar inverters are tested and approved by acknowledged independent certification authorities and can only be installed by qualified professional companies.
  • Page 3 5.6. 1 PF Power Curve Mode 5.6.2 PU Curve Mode 5.6.3 QU Curve Mode 5.6.4 Power Recovery Rate 6. TROUBLESHOOTING 7. TECHNICAL PARAMETERS 8. PRODUCT END-OF-LIFE 9. DISCLAIMER OF LIABILITY 10. CONTACT AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 4: Preliminary Remarks

    This section describes relevant warning Each inverter can be identified by means of symbols recurring in the installation and the following information: operation manual of AEG solar inverters. Icons highlight relevant information for the Product Label physical and property safety of the user.
  • Page 5: Safety

    RISK OF ELECTRIC SHOCK including, without limitation, the risk of DC connectors provided If your AEG inverter has 2 MPPT (or more), ONLY USE THE ORIGINAL make sure to connect a balanced amount of solar PV panels to each MPPT AC &...
  • Page 6: Installation And Maintenance Safety

    DC voltages. inverter, allow it to cool down first. Installers and operators should carefully follow the instructions in this manual when handling the inverter and avoid hazardous AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 7: Product Overview

    3.PRODUCT OVERVIEW the package content as described in 2.2 Handling safety. 3.1 Inverter overview The package content of your AEG inverter will include: 3 4 5 Inverter 1x wall-mount bracket Item Description During normal operation it is „on“. It can shut down...
  • Page 8: Installation

    • The inverter is best installed at eye 4. Mount the inverter onto the wall-mount level. This facilitates maintenance and bracket. allows the best visibility of product AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 9: Electrical Connection

    85mm strained. 170mm expansion pipe mounting bracket There are two AC connector brands compatible with the AEG inverters of this 20mm product series: VACONN and Exceedconn. Choose one of these to connect the 85mm inverter to the grid. 170mm...
  • Page 10: Ac Circuit Breaker And Leakage Current Protection Device

    0.6N.m) the connector of AC cable into the corresponding terminal. 3. Only the DC connectors supplied in the 4.3.2 AC circuit breaker and leakage package are suitable for use with the AEG current protection device inverter. Please install an independent two-pole 4. The positive (=red) and negative...
  • Page 11: Earth Terminal Connection

    Use tools that are specifically designed for crimping 4.3.4 Earth Terminal Connection The inverter is equipped with earth terminal according to the requirement of EN 50178. conductive exposed metal parts of the AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 12: Communication Connection

    4.4.1 WiFi Communication WiFi communication requires the installation and configuration of the WiFi communication module. The picture below shows the WiFi module installation mode for AS-IR02 series 4.4.3 RS 485 Communication The connection steps for RS485 communication are described in the below...
  • Page 13: Dred / Remote Shutdown / Ct (Power Limit Device) Connection

    Step 1: Dismantle the resistor or shortcircuit 4.4.4 Export Power Limit (CT device) cable. connection scheme The methods of connecting the Power Limiting device (CT device) are described in the below scheme: AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 14 Content+ REFGEN Content- COM/DRM0 Remote Shutdown Step 3: Connect the terminal at the right Please connect the cables in the order position to the inverter. shown in the below table. AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 15: Earth Fault Alarm

    To monitor your AEG inverter you can rely on the AEG Monitoring Portal. Go to www.aeg-industrialsolar.de/solar-inverters (section: AEG Inverter Monitoring) and follow the instructions there for the App download. Please note that the App itself is subject to update without notification.
  • Page 16: User Interface And System Configuration

    Line ① seconds. Items that are locked can be Line ② unlocked by short pressing the button or by switching mode (e.g.: from „Normal“ to „Utility loss“). AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 17: The Menu

    Short press to select Set Addr: Long Press Press number 0 ~ 9 Long Press Set Calibrate Addr Set Addr: XXX Short press to select Pac=2595.5W number 0 ~ 9 AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 18: Basic Settings

    „Set Long press the button to enter the second Time“ menu. Long press the button to level menu of error detection. The latest enter the second level menu. The initial AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 19: Power Limiting Function Settings

    Password Input menu. The initial is turned on. Long press the button to display „1111“ is the default password. Short disable the function. press the button to increase the number AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 20: Auto-Test

    „Auto Test“, and long press the commissioning button to initiate the function. When the Auto Test is finished, short press When the input voltage reaches the the button until the LCD displays „Auto AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 21: Error Messages

    After activating the function please specific software. Should you need to adjust configure the WiFi again. these setpoints, please contact the AEG Technical Support. Following is an overview Short press the button until the LCD displays of these special setpoints: „WiFi Reset“, then long press the button...
  • Page 22: Pf Power Curve Mode

    230V 0~120 power ratio (100%*Pn) (100%*Pn) 235V~ 250V 244V voltage ratio 255V 0~120 power ratio (100%*Pn) (100%*Pn) 244V~ 265V 255V voltage ratio 265V 0~120 power ratio (20%*Pn) (20%*Pn) AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 23: Qu Curve Mode

    PV panels. This will not Q3 reactive lead to inverter damage. power ratio (0%*Pn) (0%*Pn) 265V 255V 244V~265V voltage ratio Q4 reactive 0~60 power ratio (-30%*Pn) (-30%*Pn) AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 24 The internal temperature is higher than the specified normal value. Over Reduce ambient temperature. Temperature Move the inverter to a cool place. If the problem persists, contact your reseller. AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 25 WiFi communication module. Please change connect to the password. It should only consist of numbers and/or network uppercase / lowercase letters. If the problem persists, contact your reseller. AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 26: Technical Parameters

    Operating Altitude (m) ≤4000 Cooling Natural Convection User Interface LCD & LED Communication WIFI (optional: LAN or RS485) Communication Protocol Modbus Weight (kg) Size (Width*Height*Depth mm) 295*230*113 Noise Emission (dB) AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 27 97.6% 97.6% European Efficiency 97.0% 97.2% 97.2% Protection DC Insulation Resistance Detection Integrated Residual Current Monitoring Unit Integrated Anti-islanding Protection Integrated AC Overcurrent Protection Integrated AC Short Circuit Protection Integrated AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 28 For example, appliances, electricity meters, primary overcurrent portable tools and other plug- protection equipment and other connected equipment. equipment connected directly to • Category III: applies to fixed outdoor open lines. AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...
  • Page 29: Product End-Of-Life

    Or dry, non www.aeg-industrialsolar.de conductive pollution becomes Mail: service@aeg-industrialsolar.de conductive due to condensation, which is expected. AEG is a registered trademark used under license • Pollution degree 4: Persistent from AB Electrolux (publ). conductive pollution occurs. For example, the pollution cause by conductive dust, rain and snow.
  • Page 30 Solar Solutions GmbH Brückenstrasse 94 60594 Frankfurt am Main, Germany www.aeg-industrialsolar.de Mail: service@aeg-industrialsolar.de AEG is a registered trademark used under license from AB Electrolux (publ). AEG INVERTER INSTALLATION MANUAL SERIES AS-IR02 VERSION: PD202111 V3-21 EN...

Table of Contents