1000 knot range operating limits
Parameter
Min Alt
Max Alt
Min CAS
Max CAS
Min Ps
Max Ps
Min Qc
Max Qc
Max Mach
Max ROC
Max Rate CAS
Max Rate Ps
Max Rate Qc
ARINC Limits
Alt Correction
© 2015 General Electric Company – All rights reserved.
Max Limits
-3,000 ft
105,000 ft
-100 kts
1,000 kts
3.0 mbar
1355.00 mbar
-1,352.00 mbar
2,500.00 mbar
14.97
1000,000 ft/min
2,000 kts/min
10,000.00 mbar/min
10,000.00 mbar/min
OFF
0 ft
Standard Limits
-3,000 ft
80,000 ft
0.0 kts
1,000 kts
27.615 mbar
1,128.029 mbar
-16.303 mbar
2,490.50 mbar
5
15,000 ft/min
700 kts/min
200.00 mbar/min
200.00 mbar/min
OFF
0 ft
ADTS 405 Mk2 Instruction Manual-English | 3
Operating Limits
Civil Limits
-1,000 ft
50,000 ft
0 kts
450 kts
115.972 mbar
1050.406 mbar
0 mbar
368.01 mbar
1
6,000 ft/min
600 kts/min
100.00 mbar/min
100.00 mbar/min
OFF
0 ft